UVC Mirror - UN Series
Don't see the options you're looking for? Request a custom quote
Pairs well with

UVC Mirror - UN Series
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping Information
Use this text to answer questions in as much detail as possible for your customers.
-
Customer Support
Use this text to answer questions in as much detail as possible for your customers.
-
FAQ’s
Use this text to answer questions in as much detail as possible for your customers.
-
Contact Us
Use this text to answer questions in as much detail as possible for your customers.
Absolutely Effective
Fully Automated
Totally Safe

Effective Disinfection
Our patented design enables fully automatic disinfection without human intervention in a simple and cost-effective way and is absolutely safe.
By utilizing UVC LED germicidal light, our mirror eliminates up to 99.99% (Log 4) of most common pathogens within seconds.

Disinfecting Room Air with GUV
Upper-room GUV is a safe means of air disinfection that is possible in rooms with high ceilings. This upgrade adds another disinfection unit to your UVC Mirror for the upper part of your room. Upper-room GUV disinfects large volumes of room air (above occupants’ heads) at once, resulting in high „equivalent“ air changes per hour (ACH) in terms of air disinfection only—GUV does not dilute odors or CO2.
This upgrade requires an installation with a floor height of at least 210 cm for the room air disinfection unit.
Tech Specs
Mirror
Type: Crystal Mirror
Thickness: 5 mm
Surface: Float
Tint: Neutral
Reflection: 95 % +/- 5
Sensor Area: Visible
UV Disinfection Unit
General Values
UV-C Wavelength: 275 nm
UV-A Wavelength: 400 nm
Beam Angle: 60°
Max. Radiation Intensity: 403 uW/cm2@ 25 cm
Avg. Radiation Intensity: 174 uW/cm2@ 25 cm
Projected Surface Depth: 480 mm
Mirror Width 600 mm
Projected Surface Width: 300 mm
Number of UV-C LEDs: 15
Number of UV-A LEDs: 5
UV-C Radiation Power: ≥ 37.5 mW
Power Consumption: 3 W
Current Consumption: 125 mA
Mirror Width 900 mm
Projected Surface Width: 600 mm
Number of UV-C LEDs: 30
Number of UV-A LEDs: 10
UV-C Radiation Power: ≥ 75 mW
Power Consumption: 6 W
Current Consumption: 250 mA
Mirror Width 1200 mm
Projected Surface Width: 900 mm
Number of UV-C LEDs: 45
Number of UV-A LEDs: 15
UV-C Radiation Power: ≥ 112.5 mW
Power Consumption: 9 W
Current Consumption: 375 mA
Mirror Width 1600 mm
Projected Surface Width: 1200 mm
Number of UV-C LEDs: 60
Number of UV-A LEDs: 20
UV-C Radiation Power: ≥ 150 mW
Power Consumption: 12 W
Current Consumption: 500 mA
Germidical Effectiveness
99% reduction (Log2 @ 10 mJ/cm2):57 seconds (Avg.) @ UVC Mirror installed at 200 mm above surface
99,99% reduction (Log4 @ 20 mJ/cm2):115 seconds (Avg.) @ UVC Mirror installed at 200 mm above surface
Integrated Motion Sensor
Type: The sensor is an active motion detector; it emits a high-frequency electromagnetic wave 5.8 GHz and receives its echo. The sensor detects the change in echo from movement in its detection zone.
Hf System: 5.8 GHz CW radar
Transmission Power: < 0.2 mW
Detection Angle: 30° – 150°
Detection Range: Max. 12 m in diameter, adjustable
FAQs
Please read our FAQs page to find out more.
How do I clean the product?
To avoid damages please ensure the observance of the following instructions:
• Use mild, fast-drying household spray glass cleaning solutions with ammonia and water. Ammonia concentration not to exceed 1.5% of weight.
• Use a lint-free paper cloth that is non abrasive or a soft cotton cloth without seams, buttons, plastic or metal parts.
• Pre-moisten glass surface with water or cleaning solution to loosen dried dirt and debris before attempting to wipe it away - never scrape with a metal blade or tool
• Never use abrasive household detergents as cleaning agents.
• Never attempt to remove debris /dirt from the glass by using a scraper or razor blade.
• Never trap abrasive particles between the cloth and the glass surface while wiping away the cleaning solution.
Is it easy to install the product?
For ad notam it is very important that our products can be installed easily and safely. For this reason, in contrast to other industry providers, we always supply a mounting template for surface-mounted installations. This ensures that all wall brackets are in the correct position and the installation is completed within a short time.
I heard that UVC radiation is harmful?
Our solutions meet all the safety requirements. The UVC lights are off while you are using the mirror and turn on automatically after a preset time without detection of a person.
How can I see that the disinfection process is running?
The UVC Mirror is equipped with a motion sensor to turn on and off automatically the sanitation mode. The indicator on the mirror gives you feedback whether the lights are running.
Doesn`t the humidity in bathrooms affect the product?
No, the product can be safely installed in bathrooms zone 3 (IPX2 rating). If you wish to install our products outside of zone 3, you have to contact us for guidance upfront.